Our septal superior approach for exposure of Mitral Valve and warm antegrade followed by retrograde cardiplegia offers excellent operative conditions for surgeon to do difficult Mitral Valve Repairs or Replacement. We have devised a perfect, dependable technique to test the repaired Mitral Valve with left atrium still open. READ MORE
Tissue valve are used only for patients where anticoagulation is not indicated i.e. for women in childbearing age and old individuals. Tissue valve have a limited life from seven to twelve years and they are degenerated with time. Hence there is a need to replace them when
they start malfunctioning. Regular follow up is essential for such cases. Main advantage is that patient is saved from complications of life long anticoagulation.